PVSensor Complete
| The PV Sensor system is designed for use in the Light RTM process and also the Film Infusion Process. The PVSensor is placed in the mould to give an in-mould pressure reading whilst paying attention to the atmospheric pressure. The Light RTM process relies on the pressure of the atmosphere to keep the mould closed, therefore if the resin is pumped into the mould to quickly, the pressure within the evacuated mould cavity can also exceed the outer atmospheric clamping force. The signal to the machine from the PVSensor controls the machine output therefore optimising the fill time. |
![]() |
Part Ref: 5801 for complete system
|
![]() Design Right 2003 |
|
|
PVSensor located in mould optimising resin flow
|
|
PVSensor for use with film infusion The larger PTFE Sensor body is easily attached to the chosen zone by sealing it onto the film allowing it to communicate with the cavity through a minute hole pierced in the film. In use the PVSensor first gives accurate confirmation that full vacuum has been achieved below the film prior to the start of the infusion, it is then able to detect and indicate the small differences in pressure present as the resin passes the sensor point. With such a system it is now possible to accurately monitor both the low pressures associated with film infusion. - This now leads to the real possibility of employing machinery that will mix on demand and deliver resin to the delicate film covered mould. |
![]() |
![]() |
Telephone: +44 (0) 1822 832621